Why RNA Gel Electrophoresis result have small unexpected bands?
If you are observing unexpected smaller bands in your RNA gel electrophoresis, there are several potential reasons for this observation. Here are a few possibilities:
Incomplete Transcription: The smaller bands could be the result of incomplete transcription, where the T7 RNA polymerase may terminate prematurely, resulting in shorter RNA fragments. This can happen due to various factors, such as template secondary structure, incomplete removal of inhibitors, or suboptimal reaction conditions. You can try optimizing the reaction conditions, including adjusting the concentrations of nucleotides, enzyme, template DNA, and incubation time.
RNA Degradation: RNA is susceptible to degradation by RNases, which can be present in the environment or introduced during sample handling. It is essential to use RNase-free techniques, equipment, and reagents throughout the experiment. Ensure that all solutions and buffers are RNase-free, and handle the samples carefully to minimize the risk of RNA degradation.
RNA Contamination: Contamination with smaller RNA molecules from external sources can also lead to the presence of smaller bands. This contamination can occur during sample handling, pipetting, or through airborne RNases. To minimize contamination, maintain strict aseptic techniques, use dedicated RNA workstations, and wear gloves while handling samples.
Secondary RNA Structures: The formation of secondary structures within the RNA molecules can affect their migration pattern during gel electrophoresis. These structures can lead to anomalous migration and the appearance of smaller bands. Denaturing the RNA samples by heating them before loading onto the gel can help disrupt secondary structures and improve the resolution of the bands.
Transcription Errors: Occasionally, T7 RNA polymerase can introduce errors during transcription, resulting in shorter RNA fragments. While this is less common, it can occur. Optimizing the transcription reaction conditions and using high-quality enzymes can help minimize the occurrence of transcription errors.
To troubleshoot the issue, you can try the following:
Verify the integrity of your template DNA by running it on an agarose gel to ensure it is intact and of the expected size.
Repeat the in vitro transcription reaction, ensuring that all reagents are fresh and properly stored. Optimize the reaction conditions, such as adjusting the concentrations of nucleotides, enzyme, and incubation time.
Take precautions to minimize RNA degradation and contamination by working in a clean, RNase-free environment, using dedicated equipment, and handling samples carefully.
Denature the RNA samples by heating them at 65-70°C for 5 minutes and immediately placing them on ice before loading onto the gel.
Consider verifying the size of the RNA fragments using alternative methods, such as qPCR or sequencing, to confirm the presence of smaller bands.
By systematically addressing these factors, you should be able to identify and mitigate the cause of the unexpected smaller bands in your RNA gel electrophoresis.