measure butterfly valve seat

Use a micrometer to test. The final landing point needs to pass through the center line of the butterfly valve. However, this cannot be determined by visual inspection. Therefore, a point is usually fixed with a micrometer, and the test is performed left and right. If there is no place larger than the existing size, the current test value is the DN of the butterfly valve.